Search results for "Pulmonary ventilation"
showing 10 items of 37 documents
Sputum metalloproteinase-9/tissue inhibitor of metalloproteinase-1 ratio correlates with airflow obstruction in asthma and chronic bronchitis
1998
Asthma and chronic bronchitis are inflammatory diseases with extracellular matrix (ECM) remodeling and collagen deposition. Collagen homeostasis is controlled by metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs). We evaluated MMP and TIMP balance in induced sputum of 10 control, 31 untreated asthmatic, and 16 chronic bronchitic subjects. We first performed zymographic analysis to identify the profile of MMPs. Zymography revealed a similar MMPs profile in all populations studied and that MMP-9 was the major enzyme released. We then measured, using enzyme immunoassay, the concentrations of MMP-9 and of its inhibitor TIMP-1 and evaluated whether airflow limitation m…
Ventilatory threshold during incremental running can be estimated using EMG shorts
2012
The present study examined whether shorts with textile electromyographic (EMG) electrodes can be used to detect second ventilatory threshold (V(T2)) during incremental treadmill running. Thirteen recreationally active (REC) and eight endurance athletes were measured for EMG, heart rate, blood lactate and respiratory gases during VO(2max) test (3 min ramps, 1 km·h(-1) increments). V(T)(2), onset of blood lactate accumulation (OBLA) and EMG threshold (EMG(T)) were determined. In athletes, OBLA occurred at 56 ± 6 mL·kg(-1)·min(-1), V(T2) occurred at 59 ± 6 mL·kg(-1)·min(-1), and EMG(T) at 62 ± 6 mL·kg(-1)·min(-1) without significant differences between methods (analysis of variance: ANOVA). In…
Ventilatory chemosensitivity, cerebral and muscle oxygenation, and total hemoglobin mass before and after a 72-day mt. Everest expedition.
2014
Abstract. Cheung, Stephen S, Niina E. Mutanen, Heikki M. Karinen, Anne S. Koponen, Heikki Kyro ̈ la ̈ inen, Heikki O. Tikkanen, and Juha E. Peltonen. Ventilatory chemosensitivity, cerebral and muscle oxygenation, and total hemoglobin mass before and after a 72-day Mt. Everest expedition. High Alt Med Biol 15:331–340, 2014.— Background: We investigated the effects of chronic hypobaric hypoxic acclimatization, performed over the course of a 72-day self-supported Everest expedition, on ventilatory chemosensitivity, arterial saturation, and tissue oxygenation adaptation along with total hemoglobin mass (tHb-mass) in nine experienced climbers (age 37 – 6 years, _ VO 2peak 55 – 7mL $ kg - 1 $ min…
Monosodium benzoate hypersensitivity in subjects with persistent rhinitis
2004
Background: Very few data are available from the literature on whether nonatopic subjects affected by persistent rhinitis may show the appearance of objective symptoms of rhinitis after the ingestion of food additives such as tartrazine (E102), erythrosine (E127), monosodium benzoate (E211), p-hydroxybenzoate (E218), sodium metabisulphite (E223), and monosodium glutamate (E620). It is still unclear whether the ingestion of food additive may cause, as well, a consensual reduction of nasal peak inspiratory flow (NPIFR). Therefore, we used a double-blind placebo-controlled (DBPC) study to evaluate this hypothesis. Patients and methods: Two hundred and twenty-six consecutive patients (76 male…
Hyperpolarized helium-3 gas magnetic resonance imaging of the lung.
2003
3He magnetic resonance imaging (MRI) is capable of producing new and regional information on normal and abnormal lung ventilation. The basis of 3He MRI involves "optical pumping" to hyperpolarize the 3He nuclei by photon angular momentum transfer. The hyperpolarized gas is administered via inhalation. 3He is an inert, nontoxic noble gas and absorbed in less than 0.1%. Imaging consists of a four-step protocol. 1) Gas density 3He MRI with high spatial resolution displays the distribution of a 3He bolus in a 10-second breath-hold. An almost homogeneous distribution is regarded as normal. Patients with lung diseases show multiple ventilation defects. 3He MRI has been shown to be more sensitive …
Imaging of the lungs using 3he MRI: Preliminary clinical experience in 18 patients with and without lung disease
1997
The purpose of this study was to describe the 3He MRI findings of normal pulmonary ventilation in healthy volunteers and to evaluate abnormalities in patients with different lung diseases. Hyperpolarized 3He gas (300 ml, 3 x 10(5) Pa, polarized to 35-45% by optical pumping, provided in special glass cells) was inhaled by 8 healthy volunteers and 10 patients with different lung diseases. Imaging was performed with a three-dimensional fast low-angle shot (FLASH) sequence (TR = 11.8 msec; TE = 5 msec; transmitter amplitude, 5-8 V; corresponding flip angle, < 5 degrees) in a single breath-hold (22-42 seconds). Clinical and radiological examinations were available for correlation. The studies we…
Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT)
2013
BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) …
Nasal airway, lip competence, and craniofacial morphology
1993
The aim of the present investigation was to demonstrate whether children selected by their open lip posture show differences in their nasal airway resistance and facial morphology compared to children with closed lip closure. Thirty-two children with poor lip competence were compared to a control group of 20 with secure mouth closure. Patients with poor lip competence showed a significantly higher ML-NSL angle and also ML-NL angle. Anterior rhinomanometry, as well as measurements of the pharyngeal space on lateral headfilms, displayed no significant differences between the two groups. The same material was also grouped cephalometrically into skeletal open and skeletal deep bite configuratio…
Intrapulmonary 3He Gas Distribution Depending on Bolus Size and Temporal Bolus Placement
2008
OBJECTIVE: Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on inspiratory gas distribution. MATERIALS AND METHODS: An ultrafast 2-dimensional spoiled gradient echo sequence (temporal resolution 100 milliseconds) was used for dynamic ventilation (3)He-MRI of 11 anesthetized and mechanically ventilated pigs. The applied (3)He gas bolus was varied in volume between 100 and 200 mL. A 150-mL bolus was varied in its application time after the beg…
A model of stepwise isovolaemic blood exchange in anaesthetised, spontaneously breathing rats to evaluate the oxygen transport efficiency of artifici…
2000
Our research pursues the production of hypo-oncotic artificial oxygen carriers, based on artificial covalently cross-linked hyperpolymeric mammalian haemoglobins. To evaluate their in vivo efficiency in oxygen delivery to the tissue we developed a small animal model of stepwise isovolaemic blood exchange in anaesthetised, spontaneously breathing rats. With the aid of a two-way respiratory micro valve for small animals the overall oxygen uptake by the tissue of the animal can be determined. Measurements of oxygen contents in arterial and mixed venous blood and of some further blood parameters together with known oxygen-binding characteristics of artificial and native oxygen carriers, permits…